Refrigerant Compressor
The ISH series is a design contributing to a large field of operation and lower installation cost, without the need for additional water cooling circuits. All designed to work efficiently in almost any type of industrial refrigeration installation for cooling or freezing applications.
Features of IS Series
Capacity Chart 1 to 6 Cylinders
Compressor Model | Refrigerant Evaporating Temp. in °C | NH3 | R-22 | ||||||
35 °C | 40 °C | 35 °C | 40 °C | ||||||
Capacity | Power | Capacity | Power | Capacity | Power | Capacity | Power | ||
IS-200 | 5 | 283.6 | 46.3 | 271.86 | 51.8 | 250.58 | 51 | 237.56 | 55.3 |
0 | 230.81 | 45.1 | 220.81 | 49.8 | 208.6 | 48.7 | 197.09 | 52.7 | |
-5 | 186.4 | 43.1 | 177.33 | 47 | 171 | 46.3 | 161.3 | 49.8 | |
-10 | 147.67 | 40.4 | 139.42 | 43.3 | 139.77 | 43.6 | 130.81 | 46.6 | |
-15 | 114.53 | 36.8 | 105.1 | 38.6 | 111.98 | 40.6 | 104.19 | 43 | |
IS-300 | 5 | 424.53 | 68.5 | 407.79 | 76.7 | 375.93 | 75.5 | 356.28 | 82 |
0 | 346.28 | 66.6 | 331.28 | 73.8 | 312.91 | 72.1 | 295.58 | 78 | |
-5 | 279.53 | 63.7 | 265.93 | 69.6 | 257.56 | 68.4 | 242.44 | 73.7 | |
-10 | 221.51 | 59.6 | 209.19 | 63.9 | 209.65 | 64.4 | 196.28 | 69 | |
-15 | 171.74 | 54.2 | 158.5 | 54.7 | 168.02 | 59.9 | 156.4 | 63.5 | |
IS-400 | 5 | 566.05 | 90.6 | 543.72 | 101.6 | 501.28 | 100 | 475.12 | 108.6 |
0 | 461.74 | 88.2 | 441.74 | 97.7 | 417.21 | 95.5 | 394.19 | 103.4 | |
-5 | 372.79 | 84.3 | 354.65 | 92.1 | 343.49 | 90.6 | 323.26 | 97.7 | |
-10 | 295.35 | 78.8 | 278.84 | 84.6 | 279.53 | 85.2 | 261.74 | 91.3 | |
-15 | 229.07 | 71.5 | 210.7 | 75 | 224.07 | 79.2 | 208.49 | 84 | |
IS-600 | 5 | 849.07 | 134.8 | 815.7 | 151.3 | 751.98 | 148.9 | 712.67 | 161.8 |
0 | 692.67 | 131.1 | 662.67 | 145.4 | 625.81 | 142.1 | 591.28 | 154 | |
-5 | 559.19 | 125.3 | 531.98 | 137 | 515.23 | 134.8 | 485 | 145.4 | |
-10 | 443.02 | 117.1 | 418.37 | 125.8 | 419.3 | 126.7 | 392.67 | 135.8 | |
-15 | 343.6 | 106.2 | 316.6 | 111.5 | 336.16 | 117.7 | 312.79 | 124.9 |
Engineering Data
Type of Compressor |
| IS-2 | IS-3 | IS-4 | IS-6 |
Cylinder Arrangement |
| V | W | 2 x V | 2 x W |
Number of Cylinders |
| 2 |
|
|
|
Cylinder Bore | mm | 6.29 (160) | |||
Piston Stroke | mm | 4.3 (110) | |||
Permissible Speed RPM | V Belt Drive | ||||
Swept Volume of Suction Gas | m3 /hr | 265.9 | 398.5 | 531.1 | 796.5 |
Direction of Rotation / | Clockwise | ||||
Maximum Discharge pressure | bar | 295 (21) |
Conditions
METALEX CRYOGENICS LTD.
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |